SXJ-D Digital USB Joulemeters - NEW!

USB Powered, Software Driven Joulemeter Probes.


These incredible new Joulemeter probes are powered through the USB port on your laptop or desk top computer. LabView Applications Software gives you full instrument controls like range, trigger level, wavelength correction, area factor, etc. Measure, collect data, analyze and plot your measurements.

Packaged in a unique modular housing that includes the Pyroelectric or Silicon sensor, fast integrating circuit, microprocessor and USB connection - these probes are easy to incorporate into a single, dual or multi-channel system - limited only by the number of USB ports available.

SPJ-D-8 and SPJ-D-8-OB Pyroelectric Joulemeter

These Joulemeter probes include a 7.8 mm square Pyroelectric detector element - one with a fast, Chromium coating for use at high rep rates (1,000 pps) - and the other with a Black Absorbing coating for high output and flat spectral response from 0.1 to 1000 µm. Measure from 50 nJ to 50 mJ and from fsec to µsec pulses.

SSJ-D-5 and SSJ-D-10 Silicon Joulemeter

Our Silicon Joulemeter probes are based on UV enhanced Photodiodes and are incredibly sensitive in the 0.2 to 1.1 µm spectral range. Measure from fJ to µJ, from a single pulse to 1000 pps and from fsec to µsec pulses.

Features common to both single and dual channel Application Software:

  • Live display in J or J/cm2
  • Statistics; min, max and standard deviation
  • Graphic displays; strip chart, histogram and tuning
  • Wavelength correction
  • Window transmission correction (attenuation)
  • Background Null (offset)
  • Controls include range, trigger level
  • Data file and analysis mode (stats and graphs)

Dual Channel Features:

  • Display A, B and Ratio simultaneously
  • Ratio A/B or B/A in decimal format
  • 2CH data collection with time stamp
  • Full data analysis and graphics for A, B and Ratio

Datasheets (Acrobat PDF)


SXJ-D Digital USB Joulemeter

Related Products:


SXJ-A Analog Joulemeters



SXJ-D Digital USB Joulemeters

. SPJ-D-8 SPJ-D-8-0B SSJ-D-5 SSJ-D-10 Units & Notes
.
Wavelength Range 0.1 to 1000 0.1 to 1000 0.2 to 1.1 0.2 to 1.1 µm
Energy Range 2 µJ to 20 mJ 2 µJ to 20 mJ 2 pJ to 20 nJ 2 pJ to 20 nJ
Energy Resolution 10 nJ 10 nJ 10 fJ 10 fJ
Max Rep Rate 1000 400 1000 1000 PPS
Max Pulse Width 15µsec 15µsec 15µsec 15µsec
Max Average Power 500 500 1 1 mW/cm2
Detector Size 7.8x7.8 7.8x7.8 5 10 mm
Detector or Coating Type Pyro/Chrome Pyro/Black Silicon Silicon
Analog Voltage Output 0-2 0-2 0-2 0-2 V
Power Supply USB USB USB USB
Price in USD CALL or e-mail CALL or e-mail CALL or e-mail CALL or e-mail








ABOVE: Single CH Screen with live stats and strip chart


ABOVE: Single CH Screen with tuning needle


ABOVE: Dual CH Screen with CHA, CHB and Ratio


ABOVE: Dual CH Screen with CHA, CHB and Histogram