SPT-R-TRAP, SPT-AR-TRAP, SPT-DR TRAP: Pyroelectric TRAP Radiometer Probes

Precise, Spectrally flat, Power Calibration Transfer Standards


These NEW analog and digital Pyroelectric TRAP Radiometers set the standard for low uncertainty power measurements of lasers, lamps and low temperture black body sources. They are also ideal, when mated to an IR monochromator, for spectral calibration of IR detectors from 0.2 to 20 µm.

Their unique design is based on the “wedge” TRAP concepts pioneered at NIST Boulder where they are used as Spectral Calibration Transfer standards. The Pyro TRAP consists of a large area Black Pyroelectric Detector opposite a large area broadband mirror in a 15 degree wedge configuration (see the optical schematic below). The wedge configuration is designed so that 99% of the light passing through the 5 mm aperture is absorbed and measured. This means the spectral response from 0.25 to 13 &mirco;m is flat to 1% or better. It’s useful spectral range is from 0.2 to 1000 µm.

We offer three Pyroelectric TRAP Radiometer models as described below:

Model SPT-R-TRAP is a passive Pyro TRAP that is calibrated in µA/W and is designed for use with a low noise preamp and lock in amplifier or oscilloscope.

Model SPT-AR-TRAP is based on the SPI-A Analog Radiometer where we’ve replaced the single Black Pyro element with our Wedge TRAP and mated it to our low noise current mode electronics. We suggest you use this product with your standard Digital Oscilloscope or Lock In Amplifier.

Model SPT-DR-TRAP is based on the SPI-D Digital USB Radiometer where it’s mated to our digital electronics module. Measurement ranges are from 20 µW to 200 mW FS. Minimum resolution is 50 nW. Convenient LabView Applications Software and LabView Drivers make this Digital TRAP Radiometer incredibly useful in the lab. It can be set-up in a single or dual channel configuration.

Features


  • Broad, flat spectral response 0.25 to 14 µm
  • NIST Traceable calibration
  • Low calibration uncertainty < 1%
  • Energy range 100 nW to 50 mW
  • Excellent spatial uniformity
  • Analog and Digital models

Related Documents


SPT-R-TRAP Datasheet

Need more assistance? Ready to buy?


Please give us a call: (503) 697-1870
Or e-mail: info@spectrumdetector.com
Or fax us: (503) 697-0633



SPT-R-TRAP, SPT-AR-TRAP, SPT-DR TRAP: Pyroelectric TRAP Radiometer Probes

. SPT-R-TRAP SPT-AR-TRAP SPT-DR-TRAP Conditions
Passive Pyro TRAP Analog Digital .
Aperture 5 5 5 mm diam
Responsivity, RV .25 µA/W 10 KV/W N/A 0.63 µm @ 5Hz
Power Range 20µW - 20mW 20µW - 20mW 20µW - 20mW No optical attenuation
NEP, Noise Equivalent Power N/A 1.0 x 10-8 1.0 x 10-8 W/(Hz)1/2 @ 5Hz
Max Rep Rate 200 200 10 pps (OB coating)
Max Average Power 0.25 0.25 0.25 mW/cm2
Calibrated Spectral Range 0.25 to 14 µm 0.25 to 14 µm 0.25 to 14 µm µm (NIST absorbance data)
Useful Spectral Range 0.2 to 1000 0.2 to 1000 0.2 to 1000 µm (uncalibrated > 14 µm)
Price in USD CALL or e-mail CALL or e-mail CALL or e-mail .